The racking came out. The occupant load did not stay a storage factor.

InstaPreView · Published November 12, 2026 · Updated November 12, 2026
Line drawing of a tenant floor plan with demising walls and one suite outlined, titled “Warehouse to fitness studio”. InstaPreView by Byts & Bytes.

A warehouse with the racks removed and mats on the floor is not still Group S because the certificate of occupancy says storage. People are exercising in a room. That is a different function, usually a different occupancy group, and always a different occupant load.

IBC Chapter 3 classifies the use. Storage is not assembly, and a room full of people working out is not a stockroom. A gym without spectator seating is often treated as Group A-3. A very small studio sometimes gets argued as Group B. That argument is the building official's to accept. This post does not pick the group for you. Read Chapter 3 in the adopted code, describe the activity honestly on the code sheet, and ask if you are close to the line. The occupancy guide is the list of groups. The model text is at ICC. If the group changes, you are in a change of occupancy under the existing building code. The change of occupancy guide explains that path. The IEBC chapter number is not cited here.

The number that moves the exits is Table 1004.5. A storage factor spreads people thin. An exercise-room factor does not. Use the factor guide for the row, and the calculator so the area and the function are written down. Then run width in the egress width calculator. A roll-up door is not an exit because it is wide. Exit doors are Section 1010 doors: swing, hardware, and clear width, in the door guide and the panic hardware guide.

Bathrooms change with the load. The fixture count follows the new occupant load, not the warehouse's old count. See the plumbing fixture guide. An open shower room is an accessibility problem as well as a count problem. See accessible plumbing.

Confirm the edition on the jurisdictions page. A storage-to-assembly change is exactly where a city amendment to the sprinkler thresholds shows up. Read it.

Upload the existing plan and the proposed plan and run a free scan. The occupant load is the first number to get right. Everything else in the letter hangs from it.

This is advisory. It is not a determination by the authority having jurisdiction. Confirm the adopted edition and local amendments before you change a drawing.