Accessible and van parking from 2021 IBC Table 1106.2 (the same counts as 2010 ADA Table 208.2), plus ramp run length, 30-inch rise, and 60-inch landings.
Edition: 2021 IBC model text for parking counts and ramp geometry, with the 2010 ADA Standards and ICC A117.1 Section 405 for the technical ramp and landing rules.
1 van accessible. 2021 IBC Section 1106.6. 2010 ADA Standards Section 208.2.4. For every six, or fraction of six, accessible spaces, at least one is a van-accessible space.
2021 IBC Table 1106.2. The same counts are in the 2010 ADA Standards Table 208.2. Earlier IBC editions numbered this table 1106.1. Where more than one parking facility is on the site, Section 1106.2 says to calculate each facility separately.
2 runs, each rising 21 in (30 in maximum). Minimum run length at 1:12 is 252 in per run, 504 in total.
3 landings, each 60 in long in the direction of travel. Turning landings are 60 in by 60 in.
2021 IBC Section 1012.2, 2010 ADA Standards Section 405.2, and ICC A117.1 Section 405.2: running slope not steeper than 1:12. 2010 ADA Standards Section 405.7.4 and ICC A117.1 Section 405.7: landing clear length 60 inches minimum in the direction of travel.
120 parking spaces, and a ramp that rises 42 inches with a turn.
Table 1106.2 requires 5 accessible spaces. Section 1106.6 requires 1 of them to be van accessible. A 42-inch rise needs 2 runs because each run is limited to 30 inches. At 1:12, each run is 252 inches long, with 3 landings of 60 inches. The turning landing is 60 by 60 inches.
General parking reads Table 1106.2. From 501 to 1,000 spaces the table says 2 percent, rounded up to a whole space. Above 1,000 it is 20 plus one per 100, or fraction thereof, over 1,000. Hospital outpatient and rehabilitation percentages replace that table for the care-recipient and visitor spaces they name. The ramp is sized at the 1:12 maximum. A shallower slope is allowed. A slope shallower than 1:20 is not a ramp. See the accessible parking guide and the egress ramp guide.
The 2021 IBC puts the general counts in Table 1106.2. The 2010 ADA Standards put the same counts in Table 208.2. Earlier IBC editions called the table 1106.1. Van spaces are one for every six accessible spaces, or fraction of six, under 2021 IBC Section 1106.6 and ADA Section 208.2.4.
Hospital outpatient facilities are 2021 IBC Section 1106.4: 10 percent of care-recipient and visitor spaces, and not less than one. Rehabilitation facilities and outpatient physical therapy are Section 1106.5: 20 percent. Section 1106.3 is the Group I-1 and Group R parking section, including a 2 percent rule, not the medical rule.
Running slope is 1:12 maximum and each run rises 30 inches maximum, from IBC Sections 1012.2 and 1012.4 and ADA Sections 405.2 and 405.6. Each landing is 60 inches long in the direction of travel under ADA Section 405.7.4 and ICC A117.1 Section 405.7. A change in direction needs a 60 inch by 60 inch landing under ADA Section 405.7.5. Cross slope is 1:48 maximum.
This calculator uses the 2021 International Building Code model text for general reference. Local amendments vary. It is not a substitute for the adopted code enforced by your authority having jurisdiction. See the jurisdiction pages for the edition a city has adopted, and scan the plan set before you rely on a result. A cell marked provisional was not confirmed from the model-code text and should not be used until you check the printed table.