Check an accessible lavatory or sink under the 2010 ADA Standards: 34 inch maximum rim height, 27 inch knee clearance 11 inches deep at 9 inches and 8 inches deep at 27 inches, 17 to 25 inch toe clearance, 30 inch width, the 30 by 48 inch clear floor space, faucets, pipe protection, and how many sinks must comply.
Edition: 2010 ADA Standards for Accessible Design, Sections 212.3, 213.3.4, 305.3 to 305.5, 306.2, 306.3, 309.4, and 606.1 to 606.5 (U.S. Department of Justice). The IBC enforces ICC A117.1, whose lavatory and knee clearance dimensions can differ by edition. Confirm the standard and edition the authority having jurisdiction enforces.
The 30 by 48 in clear floor space faces the fixture. Rim 34 in maximum; knee clearance 27 in high, 11 in deep at 9 in and 8 in deep at 27 in; toe clearance 17 in minimum; 30 in wide.
| Check | Section | Result | Summary |
|---|---|---|---|
| Approach | 2010 ADA Standards Section 606.2 | Pass | Forward approach with a clear floor space complying with 305 and knee and toe clearance complying with 306. |
| Rim or counter height | 2010 ADA Standards Section 606.3 | Pass | 34 in to the front of the higher of the rim or counter surface; 34 in maximum above the floor. |
| Knee clearance height | 2010 ADA Standards Section 306.3.1 and 306.3.3 | Pass | 27 in clear under the fixture; 27 in minimum so the 8 in deep knee space at 27 in above the floor is available. |
Where lavatories are provided in a toilet room, at least one must comply with 606 and may not be inside a toilet compartment (213.3.4). Only one bowl of a multi-bowl sink needs knee and toe clearance, and the dip of the overflow is ignored when measuring it (606.2). Soap and towel dispensers go within the 308 reach ranges (Advisory 606.1).
Dimensions in inches; 1 in = 25.4 mm. 5 lbf = 22.2 N.
A standard public lavatory, a vanity with deep toe space, and a school lavatory for children 6 through 12.
A lavatory with its rim at 34 in, 27 in of knee clearance that is 11 in deep at 9 in and 8 in deep at 27 in, 17 in of toe space, and 30 in of width passes; the 48 in clear floor space then needs 31 in of open floor in front of the fixture (305.4, 306, 606.3). If the toe space runs 24 in deep but the knee space at 9 in is only 12 in deep, just 18 in of toe space counts (306.2.4), so 30 in of floor is needed in front. A lavatory used primarily by children 6 through 12 with its rim at 31 in may have 24 in of knee clearance, so it passes (606.2 Exception 4).
The clear floor space and the knee and toe envelope are explained in the clear floor space guide (ADA 305 and 306), and how the ADA Standards, the IBC, and A117.1 fit together in the IBC vs. ADA vs. A117.1 guide. Soap and towel dispensers go within the reach ranges in the ADA reach range calculator, and the toilet and grab bars in the accessible water closet calculator. The adopted building code for a city is on its jurisdiction page.
Section 606.3 of the 2010 ADA Standards puts the front of the higher of the rim or counter surface at 34 inches maximum above the finish floor. A lavatory in a single-occupant toilet room reached only through a private office is excepted, and an adjustable dwelling unit kitchen sink may range from 29 to 36 inches where the rough-in allows a 29 inch connection.
Section 606.2 requires a forward approach with knee and toe clearance complying with 306. Knee clearance is the space 9 to 27 inches above the floor: at least 11 inches deep at 9 inches and 8 inches deep at 27 inches, 30 inches wide, and it may reduce 1 inch in depth for each 6 inches of height (306.3). Lavatories used primarily by children 6 through 12 may have 24 inches of knee clearance where the rim is 31 inches maximum.
Toe clearance is the space from the floor to 9 inches high. Where it is part of the clear floor space it must be at least 17 inches deep and 30 inches wide; no more than 25 inches counts, and space more than 6 inches beyond the knee clearance at 9 inches does not count (306.2).
606.2 allows a parallel approach at a kitchen sink in a space without a cooktop or conventional range, at wet bars, and at lavatories and sinks used primarily by children 5 and younger. Every other lavatory and sink needs a forward approach with knee and toe clearance.
Section 212.3 requires at least 5 percent, but no fewer than one, of each type of sink provided in each accessible room or space to comply with 606; mop and service sinks are excepted. Where lavatories are provided in a toilet room, at least one must comply with 606 and may not be located in a toilet compartment (213.3.4).
This calculator uses the 2010 ADA Standards for Accessible Design. Buildings permitted under the IBC must also meet ICC A117.1 as referenced by the adopted code, and some states (California, for example) have their own accessibility codes. It is not a substitute for the code enforced by your authority having jurisdiction. See the jurisdiction pages for the edition a city has adopted, and scan the plan set before you rely on a result.
Values to check. (a) ICC A117.1 (2009, 2017) lavatory, sink, and knee clearance values were not encoded; check the edition your code references. (b) Knee clearance is checked only at 9 in and 27 in above the floor; a straight profile between them is assumed, so check sloped or stepped aprons and bowls against 306.3.4 on the drawings. (c) Kitchen work surfaces (902), sink bowl depth, and the turning space of the room (304) are not checked here. (d) The 213.3.4 rule that at least one lavatory per toilet room comply and not sit in a toilet compartment, the one-bowl rule for multi-bowl sinks, and the residential cabinetry conditions are stated, not verified. (e) A dimension exactly equal to a minimum or maximum is treated as passing.