ADA Reach Range and Operable Parts Calculator (2010 ADA 308 and 309)

Find the allowed height for a switch, control, dispenser, or other operable part under the 2010 ADA Standards: forward or side reach, reach over a counter or other obstruction, the 30 by 48 inch clear floor space and alcove widths, and the 5 pound operating force.

Edition: 2010 ADA Standards for Accessible Design, Sections 205.1, 305.3, 305.7, 308.2, 308.3, and 309.4 (U.S. Department of Justice). The IBC enforces ICC A117.1, whose reach dimensions can differ by edition. Confirm the standard and edition the authority having jurisdiction enforces.

Above the finish floor or ground.
Only if the space is confined on three sides.
Pass · 2010 ADA Standards Section 308.2.1
15–48 in

Forward reach: operable parts 15 in minimum and 48 in maximum above the floor.

CheckSectionResultSummary
Highest operable part2010 ADA Standards Section 308.2.1Pass48 in above the floor; 48 in maximum.

Children's reach guidance (Advisory 308.1, not a requirement): Ages 3 and 4 20–36 in (outside); Ages 5 through 8 18–40 in (outside); Ages 9 through 12 16–44 in (outside).

Dimensions in inches; 1 in = 25.4 mm. 5 lbf = 22.2 N.

Worked example

A switch over a kitchen counter, a side reach over a 24 inch counter, and a wall control with open floor in front.

A forward reach over a counter 22 in deep is limited to 44 in, so a switch at 46 in fails (308.2.2); at 20 in deep or less it could be 48 in. A side reach over a 34 in high, 24 in deep counter allows 46 in, so the same 46 in control passes (308.3.2). With nothing in the way, a side reach from 15 to 48 in passes (308.3.1).

How this is calculated

  1. Choose the approach. Pick a forward reach (the clear floor space faces the element) or a side reach (the clear floor space is parallel to it). Section 305.5 lets the clear floor space be positioned for either approach unless a section says otherwise.
  2. Enter the operable part heights. Enter the highest and, if you like, the lowest operable part above the floor. With nothing in the way the range is 15 to 48 inches for either approach (308.2.1, 308.3.1).
  3. Add any obstruction. For a forward reach over a counter, the high reach is 48 inches up to 20 inches deep and 44 inches from 20 to 25 inches deep (308.2.2). For a side reach, an obstruction 10 inches deep or less is ignored; up to 34 inches high and 24 inches deep, the high reach is 48 inches to 10 inches deep and 46 inches beyond (308.3.2).
  4. Check the clear floor space and alcove. The clear floor space is 30 by 48 inches minimum (305.3). In an alcove, a forward approach needs 36 inches of width where the alcove is more than 24 inches deep, and a parallel approach needs 60 inches where it is more than 15 inches deep (305.7).
  5. Check the operating force. Operable parts work with one hand, without tight grasping, pinching, or twisting, at 5 pounds of force maximum (309.4).

How the ADA Standards, the IBC, and A117.1 fit together is explained in the IBC vs. ADA vs. A117.1 guide. Forward and side reach limits are explained in the ADA reach range guide (Section 308), and the clear floor space and knee and toe envelope under an obstruction in the clear floor space guide (ADA 305 and 306). Restroom accessories are checked in the accessible water closet calculator, and door hardware heights in the door maneuvering clearance calculator. The adopted building code for a city is on its jurisdiction page.

FAQ

What is the ADA reach range for switches and controls?

Under 2010 ADA Standards Sections 308.2.1 and 308.3.1, an unobstructed forward or side reach allows operable parts from 15 inches minimum to 48 inches maximum above the finish floor or ground. Section 309.3 requires operable parts to be within one or more of these reach ranges, with a 30 by 48 inch clear floor space in front of or beside them (305.3, 309.2).

How high can a control be over a counter?

For a forward reach over an obstruction, the high reach is 48 inches maximum where the reach depth is 20 inches or less, and 44 inches maximum where the reach depth is more than 20 inches, up to 25 inches maximum (308.2.2). For a side reach, the obstruction can be 34 inches high and 24 inches deep maximum; the high reach is 48 inches for a depth of 10 inches or less and 46 inches for a depth up to 24 inches (308.3.2).

How much force can an ADA operable part require?

Section 309.4 requires operable parts to work with one hand without tight grasping, pinching, or twisting of the wrist, and the activating force is 5 pounds (22.2 N) maximum. Gas pump nozzles are excepted from the 5 pound limit.

Are there exceptions to the reach range?

Yes. A side reach may pass over an obstruction 10 inches deep or less as if unobstructed (308.3.1 Exception 1). Fuel dispensers on existing curbs may be 54 inches above the vehicular way, and washer and dryer tops may be 36 inches high (308.3.2 exceptions). Section 205.1 also exempts operable parts used only by maintenance personnel, dedicated-use receptacles, floor receptacles, HVAC diffusers, and some redundant controls.

Check your full plan set →

This calculator uses the 2010 ADA Standards for Accessible Design. Buildings permitted under the IBC must also meet ICC A117.1 as referenced by the adopted code, and some states (California, for example) have their own accessibility codes. It is not a substitute for the code enforced by your authority having jurisdiction. See the jurisdiction pages for the edition a city has adopted, and scan the plan set before you rely on a result.

Values to check. (a) ICC A117.1 (2009, 2017) reach ranges were not encoded; check the edition your code references. (b) The children's reach table (Advisory 308.1) is guidance only and is shown, not enforced. (c) Knee and toe clearance under an obstruction for a forward reach (306) is not calculated; the page only notes that it is needed. (d) The Section 205.1 exceptions (maintenance-only controls, dedicated receptacles, floor receptacles, HVAC diffusers, redundant controls, and others) are listed, not applied; element-specific heights set elsewhere in the Standards (for example, 604.7 toilet paper dispensers) are not checked here. (e) A dimension exactly equal to a minimum or maximum is treated as passing.